Queclink GMT100 Especificações Página 41

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 111
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 40
GMT00 @Track Air Interface Protocol
TRACGMT100AN001 40
Tail Character
1
$
$
<Mode>: The working mode of the speed alarm.
0: Disable speed alarm.
1: Report speed alarm if the current speed is within the speed range defined by <Min
Speed> and <Max Speed>.
2: Report speed alarm if the current speed is outside the speed range defined by <Min
Speed> and <Max Speed>.
3: Report speed alarm only one time if the current speed is within or outside the speed
range defined by <Min Speed> and <Max Speed>. In this mode, <Send Interval>
will be ignored.
<Min Speed>: The lower limit speed.
<Max Speed>: The upper limit speed.
<Duration>: If the speed meets the alarm condition and maintains a period of time defined by
<Duration>, the speed alarm will be triggered.
<Send Interval>: The interval time of sending speed alarm message.
The acknowledgment message of AT+GTSPD command:
+ACK:GTSPD,
Example:
+ACK:GTSPD,080100,135790246811220,,000C,20090214093254,11F0$
Parameter
Length(byte)
Range/Format
Default
Protocol Version
6
XX0000 XXFFFF,
X{A Z,0 9}
Unique ID
15
IMEI
Device Name
<=10
'0' '9' 'a' 'z' 'A' 'Z'
Serial Number
4
0000 FFFF
Send Time
14
YYYYMMDDHHMMSS
Count Number
4
0000 FFFF
Tail Character
1
$
$
Queclink
Confidential
Vista de página 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 110 111

Comentários a estes Manuais

Sem comentários