GMT00 @Track Air Interface Protocol
TRACGMT100AN001 – 23 –
3.2.6. Digital Input Port Setting
The command AT+GTDIS is used to configure the parameters of 2 digital input ports. Input
<Ignition Detection> is dedicated for ignition detection. The digital input port 1 is customizable. If
the logical status is changed on the digital input port 1, the device will report message
+RESP:GTDIS to the backend server.
AT+GTDIS=
Example:
AT+GTDIS=gmt100,0,2,,,1,1,4,,,,,,,0005$
'0' – '9' 'a' – 'z' 'A' – 'Z'
<Ignition Detection>: ID of the ignition detection port.
<Input ID 1>: the digital input port ID.
<Sample Period>: the sampling period of the non-interruptible input port.
<Enable>: Enable or disable the interrupt input.
0: Disable
1: Enable
<Debounce Time>: The time for debouncing.