Queclink GMT100 Especificações Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 111
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
GMT00 @Track Air Interface Protocol
TRACGMT100AN001 18
<Event Mask>: Bitwise mask to configure which event report should be sent to the backend
server.
Bit 0 for +RESP:GTPNA
Bit 1 for +RESP:GTPFA
Bit 2 for +RESP:GTMPN
Bit 3 for +RESP:GTMPF
Bit 4 is reserved
Bit 5 for +RESP:GTBPN
Bit 6 for +RESP:GTBPF
Bit 7 for +RESP:GTBPL
Bit 8 for +RESP:GTBTC
Bit 9 for +RESP:GTSTC
Bit 10 for +RESP:GTSOA
Bit 11 for +RESP:GTSTT
Bit 12 for +RESP:GTANT
Bit 13 for +RESP:GTPDP
Bit 14 for the power on +RESP:GTRTL
Bit 15 for the ignition report +RESP:GTIGN and +RESP:GTIGF
Bit 16 for the ignition on location report +RESP:GTIGL
For each bit, set it to 1 to enable corresponding event report, 0 to disable.
<LED On>: Configure the working mode of power LED and GPS LED.
0: Each time the device powers on, both LED‟s will work for 30 minutes and then are
turned off deadly.
1: turn on Power LED and GPS LED if necessary.
<Info Report Enable>: Enable/disable the device information report function
(+RESP:GTINF). The device information include state of the device, ICCID, GSM signal
strength, adapter connection status, backup battery enable setting, battery voltage, charging
status, Power and GPS LED working mode, GPS on need setting, external GPS antenna
status, the last known time of GPS fix, analog input voltage, all digit inputs and outputs status,
time zone information and daylight saving setting..
0: Disable the device information report function.
1: Enable the device information report function.
<Info Report Interval>: The interval of reporting the device information.
<Location By Call>: Configure how to handle the incoming call.
0: Just hang up the call.
1: Hang up the call and report the current position (+RESP:GTLBC) to the backend
server.
2: Hang up the call and report the current position as a google maps hyperlink to
incoming call via SMS.
<Power Mode>: Terminal power supply mode. There are three cases list below:
0: The external power supply will charge the internal backup battery on need and
power for unit.
1: The external power supply will only charge the internal backup battery when
ignition on is detected. The charge process is stopped when ignition off. During
Queclink
Confidential
Vista de página 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 110 111

Comentários a estes Manuais