GMT00 @Track Air Interface Protocol
TRACGMT100AN001 – 26 –
port to trigger the IOB event. Set to 1 to use enable status as the trigger condition and 0 to use
disable status. Only when the logical status of all the input ports in one IO binding meets the
trigger condition is the IOB event triggered.
bit0: ignition detection
bit1: digital input 1
<Input Sample Period>: The period to check the status of all the digital input ports in one IO
binding. AT+GTIOB and AT+GTDIS use independent sample period to check the input port
status even for the same input port.
<Output ID>: ID of the output port to output specified wave when the trigger condition meets.
0 means no wave will be output.
Note:
If <Output ID> is set to 2 which is used for CUT relay, only <Output Status> could be used to
define how to output wave shape 1 as shown in Figure 2. In this case <Duration> and <Toggle
Times> should be empty. The following settings should keep the same with this note.
The acknowledgment message of AT+GTIOB command:
+ACK:GTIOB,
Example:
+ACK:GTIOB,060100,135790246811220,,1,0006,20090214093254,11F0$
XX0000 – XXFFFF,
X∈{„A‟ – „Z‟,‟0‟ – „9‟}
'0' – '9' 'a' – 'z' 'A' – 'Z'