GV300 @Track Air Interface Protocol
3.2.9. Analog Input Port Setting
The command AT+GTAIS is used to configure the parameters of analog input ports.
Before using analog input 1, <Pin15 Mode> in AT+GTCFG command must be set to 0.
Make sure there is analog signal connected to the corresponding analog input port before you
enable this function to that port.
¾ AT+GTAIS=
Example:
AT+GTAIS=gv300,1,0,250,2700,2,,1,1,0,0,1,,,2,1,250,2700,2,,1,1,0,0,1,,,,,,,0008$
Parameter Length(byte) Range/Format Default
Password 4~6 '0'~'9' 'a'~'z' 'A'~'Z' gv300
Analog Input ID1 1 1 1
Mode 1 0|1|2 0
Min Threshold <=4 250~2700mV
Max Threshold <=4 250~2700mV
Sample Rate <=2 0|1~12(×2s) 0
Reserved 0,TBD
Output ID 1 0~3
Output Active 1 0|1
Duration <=3 0~255(×100ms) 0
Toggle Times <=3 0~255 0
Sync with FRI 1 0|1 0
Reserved 0
Reserved 0
Analog Input ID2 1 2 2
Mode 1 0|1|2 0
Min Threshold <=4 250~2700mV
Max Threshold <=4 250~2700mV
Sample Rate <=2 0|1~12(×2s) 0
Reserved 0,TBD
Output ID 1 0~3
TRACGV300AN002 – 29 –