Queclink GL200 Especificações Página 110

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 119
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 109
GV300 @Track Air Interface Protocol
Device Name <=10 '0' – '9' 'a' – 'z' 'A' – 'Z'
Duration of Ignition On <=6 0 – 999999 sec
GPS Accuracy <=2 0 0, Last known
Speed <=5 0.0 – 999.9 km /h
Heading <=3 0 – 359
Altitude <=8 (–)xxxxx.x m
Longitude <=11 (–)xxx.xxxxxx
Latitude <=10 (–)xx.xxxxxx
GPS UTC Time 14 YYYYMMDDHHMMSS
MCC 4 0XXX
MNC 4 0XXX
LAC 4 XXXX
Cell ID 4 XXXX
Hour Meter Count 2|11 00|HHHHH:MM:SS
Mileage <=9 0.0 – 4294967.0 km
Send Time 14 YYYYMMDDHHMMSS
Count Number 4 0000 – FFFF
Tail Character 1 $ $
<Duration of Ignition On>: Duration since last time the ignition is on. If greater than 999999
seconds, report as 999999 seconds.
<Hour Meter Count>: If hour meter counter function is enabled by the command
AT+GTHMC, total hours meter counted when engine is on will be reported in this field. If
the function is disabled, this field will be filled with ‘00’. It is formatted with 5 hour digits
and 2 minute digits and 2 second digits and ranges from 00000:00:00– 99999:00:00.
¾ +RESP:GTIDN,
Example:
+RESP:GTIDN,060100,135790246811220,,,,0,4.3,92,70.0,121.354335,31.222073,2009021401
3254,0460,0000,18d8,6141,00,2000.0,20090214093254,11F0$
Parameter Length(byte) Range/Format Default
Protocol Version 6
XX0000 – XXFFFF,
X{'A' – 'Z','0' – '9'}
Unique ID 15 IMEI
TRACGV300AN002 109
Queclink
Confidential
Vista de página 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 118 119

Comentários a estes Manuais