GV300 @Track Air Interface Protocol
z Bit 11 for the power on +RESP:GTRTL
z Bit 12 for the ignition report +RESP:GTIGN and +RESP:GTIGF
z Bit 13 for the ignition on location report +RESP:GTIGL
For each bit, set it to 1 to enable corresponding event report, 0 to disable.
<Pin15 Mode>: Configure the working mode of the 15 pin on the connector.
z 0: Analog input 1.
z 1: Digital input 3.
<LED On>: Configure the working mode of power LED and GPS LED.
z 0: Each time the device powers on, both LED’s will work for 30 minutes and then are
turned off deadly.
z 1: turn on Power LED and GPS LED if necessary.
<Info Report Enable>: Enable/disable the device information report function
(+RESP:GTINF). The device information include state of the device, ICCID, GSM signal
strength, voltage of external power supply, battery voltage, charging status, Power and GPS
LED working mode, GPS on need setting, external GPS antenna status, the last known time
of GPS fix, analog input voltage, all digit inputs and outputs status, time zone information
and daylight saving setting..
z 0: Disable the device information report function.
z 1: Enable the device information report function.
<Info Report Interval>: The interval of reporting the device information.
<Location By Call>: Configure how to handle the incoming call if <Mode> in AT+GTMON
is not equal to 2 or 3.
z 0: Just hang up the call.
z 1: Hang up the call and report the current position (+RESP:GTLBC).
<Echo suppression>: Configure to one of the two phases for echo suppression.
z 1: Cancel and suppress echo.
z 2: Cancel and strongly suppress echo.
<Backup Battery Charge Mode>: Control the charge mode of the backup battery.
z 0: When the main power supply is connected, charge the backup battery on need.
z 1: When the main power supply is connected, only charge the backup battery when
ignition on is detected. The charge process will begin 3 minutes after the ignition on.
The charge process is stopped when ignition off.
The acknowledgment message of AT+GTCFG command:
¾ +ACK:GTCFG,
Example:
+ACK:GTCFG,060100,135790246811220,,0003,20090214093254,11F0$