Vista de página 55
GV300 @Track Air Interface Protocol
3.2.20. Protocol Watchdog
The AT+GTDOG command is used to reboot the device in a time based manner or upon ignition.
This helps the device avoid working in an exceptional status for a long time. Besides these two
automatically reboot method, the device also supports to use the digital input to trigger the reboot
manually.
¾ AT+GTDOG=
Example:
AT+GTDOG=gv300,1,,1,0130,,1,1,,,,,0013$
AT+GTDOG=gv300,2,30,,,,1,2,,,,,0013$
Parameter Length(byte) Range/Format Default
Password 4 – 6 '0' – '9' 'a' – 'z' 'A' – 'Z' gv300
Mode 1 0|1|2 0
Ignition Frequency <=3 10 – 120 min 60
Interval <=2 1 – 30 day 30
Time 4 HHMM 0200
Reserved 0
Report Before Reboot 1 0|1 1
Input ID 1 0|1|2 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Serial Number 4 0000 – FFFF
Tail Character 1 $ $
<Mode>: Working mode.
z 0: Disable this function
z 1: Reboot periodically according to the <Interval> and <Time> setting.
z 2: Reboot when ignition on.
<Ignition Frequency>: When the working mode is 2, if the time interval between two
adjacent ignitions is greater than the specified value, the device will automatically reboot
upon ignition on.
<Interval>: The interval to reboot the device in day.
<Time>: At what time to perform the reboot operation when <Interval> is met.
<Report Before Reboot>: Whether to report the +RESP:GTDOG message before reboot. 0